Assessment Year | 1990 |
---|---|
Principal Product | ENVELOPES |
NAICS |
n/a
|
SIC | 2677: Envelopes |
Sales Range | $5 M to 10M |
# of Employees | 70 |
Plant Area |
n/a
|
Annual Production | 316,000
pieces
|
Production Hrs. Annual | 4,200
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $76,189 | 910,903 |
kWh
|
$0.084 |
Natural Gas | $6,205 | 1,555 |
MMBtu
|
$3.99 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,704 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,802 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $980 | - |
$980
11,723
kWh
|
- | - | |
02 | 2.6214: Shut off pilots in standby equipment | $254 | - | - |
$319
-
MMBtu
|
$(-65.0) | |
03 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $637 | $500 |
$637
7,620
kWh
|
- | - | |
04 | 2.2443: Re-use or recycle hot or cold process exhaust air | $265 | $100 |
$193
2,345
kWh
|
$72
-
MMBtu
|
- | |
05 | 2.6121: Reduce hot water temperature to the minimum required | $235 | $180 | - |
$235
-
MMBtu
|
- | |
06 | 2.7122: Disconnect ballasts | $123 | $100 |
$123
1,465
kWh
|
- | - | |
07 | 2.8121: Apply for tax-free status for energy purchases | $3,210 | - |
$3,210
-
kWh
|
- | - | |
TOTAL RECOMMENDED | $5,704 | $880 |
$5,143
23,153
kWh
|
$626
-
MMBtu
|
$(-65.0) | ||
TOTAL IMPLEMENTED | $4,802 | $280 |
$4,313
13,188
kWh
|
$554
-
MMBtu
|
$(-65.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs