Assessment Year 1989
Principal Product ELECTRICAL STORAGE BATTERIES
NAICS
n/a
SIC 3691: Storage Batteries
Sales Range $5
M
to 10
M
# of Employees 120
Plant Area
n/a
Annual Production 480,000
pieces
Production Hrs. Annual 5,760
hrs
Location (State) Iowa

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $109,639 2,748,242
kWh
Natural Gas $32,249 7,500
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $3,484 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $2,900

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $1,193 $500 $1,193
29,894
kWh
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,064 $1,200 $1,064
26,671
kWh
03 2.7212: Install or upgrade insulation on hvac distribution systems $643 $2,900 $643
16,120
kWh
04 2.2443: Re-use or recycle hot or cold process exhaust air $584 $1,800 $584
14,654
kWh
TOTAL RECOMMENDED $3,484 $6,400 $3,484
87,339
kWh
TOTAL IMPLEMENTED $2,900 $4,600 $2,900
72,685
kWh
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs