| Assessment Year | 1989 |
|---|---|
| Principal Product | DIE CAST PARTS |
| NAICS |
n/a
|
| SIC | 3364: Nonferrous Die-Castings, Except Aluminum |
| Sales Range | $5 M to 10M |
| # of Employees | 100 |
| Plant Area |
n/a
|
| Annual Production | 258,000
lb
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $204,660 | 3,642,439 |
kWh
|
$0.056 |
| LPG | $93,111 | 32,765 |
MMBtu
|
$2.84 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $11,184 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $901 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $757 | $1,432 |
$757
13,482
kWh
|
- | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $658 | $150 |
$658
11,723
kWh
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $243 | $133 |
$243
4,396
kWh
|
- | |
| 04 | 2.2414: Use waste heat from hot flue gases to preheat | $9,066 | $22,000 | - |
$9,066
-
MMBtu
|
|
| 05 | 2.1122: Re-size charging openings or add a movable door on equipment | $460 | $400 | - |
$460
-
MMBtu
|
|
| TOTAL RECOMMENDED | $11,184 | $24,115 |
$1,658
29,601
kWh
|
$9,526
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $901 | $283 |
$901
16,119
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs