Assessment Year | 1988 |
---|---|
Principal Product | PRINTING & PUBLISHING |
NAICS |
n/a
|
SIC | 2731: Books: Publishing, or Publishing and Printing |
Sales Range | $5 M to 10M |
# of Employees | 130 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 4,632
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $61,748 | 1,038,980 |
kWh
|
$0.059 |
Natural Gas | $3,001 | 676 |
MMBtu
|
$4.44 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $12,094 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,486 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,442 | $9,509 |
$4,442
74,736
kWh
|
- | - | |
02 | 2.4239: Eliminate or reduce compressed air usage | $2,665 | - |
$2,665
44,842
kWh
|
- | - | |
03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $2,434 | $2,355 |
$3,571
60,082
kWh
|
$(-1,137.0)
-
MMBtu
|
- | |
04 | 2.2621: Modify refrigeration system to operate at a lower pressure | $1,359 | $2,400 |
$1,359
22,860
kWh
|
- | - | |
05 | 2.2437: Recover waste heat from equipment | $404 | $125 | - |
$404
-
MMBtu
|
- | |
06 | 2.6121: Reduce hot water temperature to the minimum required | $324 | - |
$244
4,103
kWh
|
$80
-
MMBtu
|
- | |
07 | 2.1123: Install automatic stack damper | $178 | $275 | - |
$178
-
MMBtu
|
- | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $174 | $10 |
$174
2,931
kWh
|
- | - | |
09 | 2.1233: Analyze flue gas for proper air/fuel ratio | $114 | - | - |
$164
-
MMBtu
|
$(-50.0) | |
TOTAL RECOMMENDED | $12,094 | $14,674 |
$12,455
209,554
kWh
|
$(-311.0)
-
MMBtu
|
$(-50.0) | ||
TOTAL IMPLEMENTED | $9,486 | $12,309 |
$8,710
146,541
kWh
|
$826
-
MMBtu
|
$(-50.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs