Assessment Year | 1987 |
---|---|
Principal Product | COMM. FOOD SERVICE EQUIP |
NAICS |
n/a
|
SIC | 2599: Furniture and Fixtures, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 70 |
Plant Area |
n/a
|
Annual Production | 5,800
pieces
|
Production Hrs. Annual | 3,500
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $19,737 | 228,019 |
kWh
|
$0.087 |
Natural Gas | $5,652 | 1,607 |
MMBtu
|
$3.52 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,783 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $428 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,999 | $4,672 |
$2,999
34,584
kWh
|
- | - | |
02 | 2.4312: Improve lubrication practices | $356 | - |
$356
4,103
kWh
|
- | - | |
03 | 2.6214: Shut off pilots in standby equipment | $142 | - | - |
$162
-
MMBtu
|
$(-20.0) | |
04 | 2.4221: Install compressor air intakes in coolest locations | $178 | $100 |
$178
2,052
kWh
|
- | - | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $108 | - | - |
$208
-
MMBtu
|
$(-100.0) | |
TOTAL RECOMMENDED | $3,783 | $4,772 |
$3,533
40,739
kWh
|
$370
-
MMBtu
|
$(-120.0) | ||
TOTAL IMPLEMENTED | $428 | $100 |
$178
2,052
kWh
|
$370
-
MMBtu
|
$(-120.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs