| Assessment Year | 1986 |
|---|---|
| Principal Product | MULTI-WALLED PAPER BAGS |
| NAICS |
n/a
|
| SIC | 2674: Uncoated Paper and Multiwall Bags |
| Sales Range | $10 M to 50M |
| # of Employees | 250 |
| Plant Area |
n/a
|
| Annual Production | 24,000
ton
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Kansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $187,025 | 3,004,982 |
kWh
|
$0.062 |
| Natural Gas | $53,411 | 12,069 |
MMBtu
|
$4.43 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $27,277 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $17,207 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,354 | $200 |
$8,354
134,232
kWh
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,299 | $6,408 |
$8,299
133,353
kWh
|
- | - | |
| 03 | 2.7229: Air condition only space necessary | $2,153 | $1,032 | - |
$2,153
-
MMBtu
|
- | |
| 04 | 2.1123: Install automatic stack damper | $1,847 | $1,900 | - |
$1,847
-
MMBtu
|
- | |
| 05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $816 | - | - |
$1,316
-
MMBtu
|
$(-500.0) | |
| 06 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,390 | $100 |
$2,390
-
kWh
|
- | - | |
| 07 | 2.4312: Improve lubrication practices | $2,627 | $1,700 |
$2,627
42,204
kWh
|
- | - | |
| 08 | 2.2511: Insulate bare equipment | $293 | $200 |
$328
5,275
kWh
|
$(-35.0)
-
MMBtu
|
- | |
| 09 | 2.2511: Insulate bare equipment | $261 | $300 |
$292
4,689
kWh
|
$(-31.0)
-
MMBtu
|
- | |
| 10 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $237 | - |
$237
3,810
kWh
|
- | - | |
| TOTAL RECOMMENDED | $27,277 | $11,840 |
$22,527
323,563
kWh
|
$5,250
-
MMBtu
|
$(-500.0) | ||
| TOTAL IMPLEMENTED | $17,207 | $7,108 |
$17,273
277,549
kWh
|
$(-66.0)
-
MMBtu
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs