Assessment Year | 1984 |
---|---|
Principal Product | FIBERGLASS CAMPER SHELLS |
NAICS |
n/a
|
SIC | 3792: Travel Trailers and Campers |
Sales Range | $5 M to 10M |
# of Employees | 75 |
Plant Area |
n/a
|
Annual Production | 10,000
pieces
|
Production Hrs. Annual | 4,800
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $25,704 | 309,203 |
kWh
|
$0.083 |
Natural Gas | $23,581 | 4,610 |
MMBtu
|
$5.12 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,271 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,864 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,484 | $300 |
$4,484
53,927
kWh
|
- | - | |
02 | 2.1123: Install automatic stack damper | $4,147 | $3,200 | - |
$4,147
-
MMBtu
|
- | |
03 | 2.2532: Use only amount of air necessary to prevent explosion hazard | $2,531 | $178 |
$268
3,224
kWh
|
$2,263
-
MMBtu
|
- | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $2,023 | $1,273 |
$2,023
24,326
kWh
|
- | - | |
05 | 2.1232: Keep boiler tubes clean | $942 | $64 | - |
$942
-
MMBtu
|
- | |
06 | 2.2437: Recover waste heat from equipment | $876 | $1,200 | - |
$876
-
MMBtu
|
- | |
07 | 2.1233: Analyze flue gas for proper air/fuel ratio | $268 | $50 | - |
$768
-
MMBtu
|
$(-500.0) | |
TOTAL RECOMMENDED | $15,271 | $6,265 |
$6,775
81,477
kWh
|
$8,996
-
MMBtu
|
$(-500.0) | ||
TOTAL IMPLEMENTED | $11,864 | $4,887 |
$6,507
78,253
kWh
|
$5,857
-
MMBtu
|
$(-500.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs