| Assessment Year | 1982 |
|---|---|
| Principal Product | WASTE WATER TREATMENT EQUIPMENT |
| NAICS |
n/a
|
| SIC | 3589: Service Industry Machinery, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
n/a
|
| Annual Production | 900
pieces
|
| Production Hrs. Annual | 2,083
hrs
|
| Location (State) | Kansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $96,623 | 1,637,456 |
kWh
|
$0.059 |
| Natural Gas | $28,604 | 9,952 |
MMBtu
|
$2.87 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $20,130 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,751 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6212: Turn off equipment during breaks, reduce operating time | $12,933 | - |
$12,933
219,226
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,751 | $7,500 |
$1,751
28,722
kWh
|
- | |
| 03 | 2.6212: Turn off equipment during breaks, reduce operating time | $2,027 | $287 |
$647
10,844
kWh
|
$1,380
-
MMBtu
|
|
| 04 | 2.2711: Utilize outside air instead of conditioned air for drying | $738 | $1,800 | - |
$738
-
MMBtu
|
|
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,547 | - |
$1,547
26,377
kWh
|
- | |
| 06 | 2.2437: Recover waste heat from equipment | $1,134 | $800 | - |
$1,134
-
MMBtu
|
|
| TOTAL RECOMMENDED | $20,130 | $10,387 |
$16,878
285,169
kWh
|
$3,252
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $1,751 | $7,500 |
$1,751
28,722
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs