Assessment Year | 1982 |
---|---|
Principal Product | MOLDED PLASTIC PARTS |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 60 |
Plant Area |
n/a
|
Annual Production | 2,000,000
lb
|
Production Hrs. Annual | 6,312
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $107,633 | 1,956,038 |
kWh
|
$0.055 |
Natural Gas | $4,064 | 1,508 |
MMBtu
|
$2.69 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $50,857 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $14,570 | - |
$14,570
264,947
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,434 | - |
$2,434
44,256
kWh
|
- | |
03 | 2.2511: Insulate bare equipment | $3,756 | $475 |
$3,756
68,288
kWh
|
- | |
04 | 2.7494: Install storm windows and doors | $1,984 | $568 | - |
$1,984
-
MMBtu
|
|
05 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $28,113 | $40,000 |
$28,113
511,137
kWh
|
- | |
TOTAL RECOMMENDED | $50,857 | $41,043 |
$48,873
888,628
kWh
|
$1,984
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs