| Assessment Year | 2026 |
|---|---|
| Principal Product | Car Metal Part Stamping |
| NAICS | 336370: Motor Vehicle Metal Stamping |
| SIC | 3465: Automotive Stampings |
| Sales Range | $100 M to 500M |
| # of Employees | 300 |
| Plant Area |
400,000
ft2
|
| Annual Production | 750,000
pieces
|
| Production Hrs. Annual | 4,080
hrs
|
| Location (State) | South Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $1,028,997 | 14,627,098 |
kWh
|
$0.070 | |
| Natural Gas | $73,562 | 5,364 |
MMBtu
|
$13.71 | |
| Waste Disposal Costs | |||||
| Water Usage | $14,551 | 3,504 |
Tgal
|
$4.15 | |
| Water Disposal | $7,959 | 3,504 |
Tgal
|
$2.27 | |
| TOTAL YEARLY COSTS | $1,125,069 | ||||
| RECOMMENDED SAVINGS* | $168,257 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $13,890 | $6,920 |
$13,890
198,431
kWh
|
- | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,304 | $60 |
$3,304
43,341
kWh
|
- | |
| 03 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $14,554 | $10,760 | - |
$14,554
-
MMBtu
|
|
| 04 | 2.7134: Use photocell controls | $720 | $4,700 |
$720
10,283
kWh
|
- | |
| 05 | 2.9114: Use solar heat to make electricty | $135,789 | $1,778,000 |
$135,789
1,939,846
kWh
|
- | |
| TOTAL RECOMMENDED | $168,257 | $1,800,440 |
$153,703
2,191,901
kWh
|
$14,554
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs