| Assessment Year | 2026 |
|---|---|
| Principal Product | Car Plastic Parts |
| NAICS | 336390: Other Motor Vehicle Parts Manufacturing |
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $50 M to 100M |
| # of Employees | 269 |
| Plant Area |
11,000
ft2
|
| Annual Production | 6,000,000
units
|
| Production Hrs. Annual | 2,500
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $965,885 | 9,759,904 |
kWh
|
$0.099 | |
| Natural Gas | $19,801 | 2,569 |
MMBtu
|
$7.71 | |
| Waste Disposal Costs | |||||
| Water Usage | $7,923 | 1,968 |
Tgal
|
$4.03 | |
| Water Disposal | $11,756 | 1,968 |
Tgal
|
$5.97 | |
| TOTAL YEARLY COSTS | $1,005,365 | ||||
| RECOMMENDED SAVINGS* | $85,376 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,578 | $6,440 |
$7,578
76,542
kWh
|
- | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,308 | $90 |
$1,308
13,207
kWh
|
- | |
| 03 | 2.2522: Isolate hot or cold equipment | $4,312 | $3,012 |
$4,312
43,556
kWh
|
- | |
| 04 | 2.8121: Apply for tax-free status for energy purchases | $555 | $800 | - | $555 | |
| 05 | 2.9114: Use solar heat to make electricty | $71,623 | $722,120 |
$71,623
723,462
kWh
|
- | |
| TOTAL RECOMMENDED | $85,376 | $732,462 |
$84,821
856,767
kWh
|
$555 | ||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs