Assessment Year | 2025 |
---|---|
Principal Product | Tufted Carpet |
NAICS | 314110: Carpet and Rug Mills |
SIC | 2273: Carpets and Rugs |
Sales Range | $50 M to 100M |
# of Employees | 150 |
Plant Area |
170,000
ft2
|
Annual Production | 55,000,000
units
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $114,170 | 998,040 |
kWh
|
$0.11 | |
Natural Gas | $11,520 | 1,438 |
MMBtu
|
$8.01 | |
Waste Disposal Costs | |||||
Water Usage | $1,728 | 386,100 |
Tgal
|
$0.004 | |
Water Disposal | $2,239 | 386,100 |
Tgal
|
$0.006 | |
TOTAL YEARLY COSTS | $129,657 | ||||
RECOMMENDED SAVINGS* | $56,423 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $36,808 | $345,359 |
$36,808
322,874
kWh
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,074 | $7,400 |
$9,074
79,600
kWh
|
- | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,563 | $60 |
$1,563
14,499
kWh
|
- | |
04 | 2.7135: Install occupancy sensors | $2,583 | $4,064 |
$2,583
22,656
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,395 | $35,202 |
$4,514
39,600
kWh
|
$1,881 | |
TOTAL RECOMMENDED | $56,423 | $392,085 |
$54,542
479,229
kWh
|
$1,881 | ||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs