Assessment Year | 2025 |
---|---|
Principal Product | Rubber Rollers |
NAICS | 326299: All Other Rubber Product Manufacturing |
SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 78 |
Plant Area |
100,000
ft2
|
Annual Production | 6,500
units
|
Production Hrs. Annual | 3,060
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $370,157 | 2,900,296 |
kWh
|
$0.13 | |
Natural Gas | $143,389 | 32,709 |
MMBtu
|
$4.38 | |
Waste Disposal Costs | |||||
Water Usage | $30,869 | 3,385 |
Tgal
|
$9.12 | |
Water Disposal | $37,947 | 3,385 |
Tgal
|
$11.21 | |
TOTAL YEARLY COSTS | $582,362 | ||||
RECOMMENDED SAVINGS* | $174,439 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,199 | $5,960 |
$7,199
56,244
kWh
|
- | - | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,218 | $60 |
$1,218
9,514
kWh
|
- | - | - | |
03 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $771 | $2,184 | - |
$771
-
MMBtu
|
- | - | |
04 | 2.8121: Apply for tax-free status for energy purchases | $22,668 | $1,600 | - | - | $5,667 | $17,001 | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $18,870 | $69,278 |
$18,870
147,418
kWh
|
- | - | - | |
06 | 2.9114: Use solar heat to make electricty | $47,984 | $340,586 |
$47,984
374,875
kWh
|
- | - | - | |
07 | 2.4133: Use most efficient type of electric motors | $8,975 | $88,610 |
$8,975
70,117
kWh
|
- | - | - | |
08 | 2.2136: Install / repair insulation on steam lines | $1,546 | $4,072 | - |
$1,546
-
MMBtu
|
- | - | |
09 | 2.3417: Use waste heat with a closed-cycle gas turbine-generator set to cogenerate electricity and heat | $65,208 | $627,000 |
$78,336
612,000
kWh
|
$(-6,728.0)
-
MMBtu
|
$(-6,400.0) | - | |
TOTAL RECOMMENDED | $174,439 | $1,139,350 |
$162,582
1,270,168
kWh
|
$(-4,411.0)
-
MMBtu
|
$(-733.0) | $17,001 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs