Assessment Year | 2023 |
---|---|
Principal Product | Electrical and Wiring Parts |
NAICS | 335931: Current-Carrying Wiring Device Manufacturing |
SIC | 3643: Current-Carrying Wiring Devices |
Sales Range | $10 M to 50M |
# of Employees | 43 |
Plant Area |
24,000
ft2
|
Annual Production | 5,400,000
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $90,773 | 684,960 |
kWh
|
$0.13 | |
Natural Gas | $11,433 | 928 |
MMBtu
|
$12.33 | |
Waste Disposal Costs | |||||
Water Usage | $939 | 119 |
Tgal
|
$7.89 | |
Water Disposal | $2,560 | 119 |
Tgal
|
$21.50 | |
TOTAL YEARLY COSTS | $105,705 | ||||
RECOMMENDED SAVINGS* | $91,377 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $34,794 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $20,360 | $1,600 | - | $5,090 | - | $15,270 | |
02 | 2.2522: Isolate hot or cold equipment | $3,369 | $3,164 |
$3,369
25,428
kWh
|
- | - | - | |
03 | 2.6212: Turn off equipment during breaks, reduce operating time | $2,204 | - |
$2,984
22,519
kWh
|
- | $(-780.0) | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,944 | $5,480 |
$3,944
29,763
kWh
|
- | - | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $80 | $89 |
$80
607
kWh
|
- | - | - | |
06 | 2.7232: Replace existing hvac unit with high efficiency model | $8,286 | $62,649 |
$8,286
62,539
kWh
|
- | - | - | |
07 | 2.9114: Use solar heat to make electricty | $53,134 | $373,105 |
$53,134
401,009
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $91,377 | $446,087 |
$71,797
541,865
kWh
|
$5,090 | $(-780.0) | $15,270 | ||
TOTAL IMPLEMENTED | $34,794 | $69,729 |
$15,214
114,821
kWh
|
$5,090 | $(-780.0) | $15,270 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs