ITAC Assessment: KS2206
ITAC logo
ITAC Assessment: KS2206
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2022
Principal Product Foodservice Warehousing and Distribution
NAICS 424410: General Line Grocery Merchant Wholesalers
SIC 5141: Groceries, General Line
Sales Range $50
M
to 100
M
# of Employees 130
Plant Area 447,000
ft2
Annual Production 129,547,668
lb
Production Hrs. Annual 6,600
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $298,055 4,554,110
kWh
Electricity Demand $21,375 5,700
kW-mo/yr
Electricity Fees $1,200 -
Natural Gas $18,093 636
MMBtu
Waste Disposal Costs
Water Usage $2,803 292
Tgal
Water Disposal $2,284 292
Tgal
TOTAL YEARLY COSTS $343,810
RECOMMENDED SAVINGS* $106,473 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $5,547

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Administrative Changes Savings
01 2.3132: Recharge batteries on during off-peak demand periods $8,106 - - $1,494
-
kW-mo/yr
$6,612 -
02 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas $5,185 - $4,700
71,873
kWh
$485
-
kW-mo/yr
- -
03 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas $2,067 $4,835 $1,122
17,155
kWh
$945
-
kW-mo/yr
- -
04 2.2522: Isolate hot or cold equipment $2,342 $3,334 $2,171
33,196
kWh
$171
-
kW-mo/yr
- -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $741 $390 $687
10,512
kWh
$54
-
kW-mo/yr
- -
06 2.7442: Keep doors and windows shut when not on use $397 - $357
5,457
kWh
$40
-
kW-mo/yr
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $2,386 $4,602 $1,137
17,382
kWh
$117
-
kW-mo/yr
- $1,132
08 2.9114: Use solar heat to make electricty $85,249 $849,734 $81,068
1,239,579
kWh
$4,181
-
kW-mo/yr
- -
TOTAL RECOMMENDED $106,473 $862,895 $91,242
1,395,154
kWh
$7,487
-
kW-mo/yr
$6,612 $1,132
TOTAL IMPLEMENTED $5,547 $8,559 $4,337
66,320
kWh
$1,210
-
kW-mo/yr
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs