| Assessment Year | 2022 |
|---|---|
| Principal Product | Foodservice Warehousing and Distribution |
| NAICS | 424410: General Line Grocery Merchant Wholesalers |
| SIC | 5141: Groceries, General Line |
| Sales Range | $50 M to 100M |
| # of Employees | 130 |
| Plant Area |
447,000
ft2
|
| Annual Production | 129,547,668
lb
|
| Production Hrs. Annual | 6,600
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $298,055 | 4,554,110 |
kWh
|
$0.065 | |
| Electricity Demand | $21,375 | 5,700 |
kW-mo/yr
|
$3.75 | |
| Electricity Fees | $1,200 | - |
|
- | |
| Natural Gas | $18,093 | 636 |
MMBtu
|
$28.47 | |
| Waste Disposal Costs | |||||
| Water Usage | $2,803 | 292 |
Tgal
|
$9.60 | |
| Water Disposal | $2,284 | 292 |
Tgal
|
$7.82 | |
| TOTAL YEARLY COSTS | $343,810 | ||||
| RECOMMENDED SAVINGS* | $106,473 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $5,547 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.3132: Recharge batteries on during off-peak demand periods | $8,106 | - | - |
$1,494
-
kW-mo/yr
|
$6,612 | - | |
| 02 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $5,185 | - |
$4,700
71,873
kWh
|
$485
-
kW-mo/yr
|
- | - | |
| 03 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $2,067 | $4,835 |
$1,122
17,155
kWh
|
$945
-
kW-mo/yr
|
- | - | |
| 04 | 2.2522: Isolate hot or cold equipment | $2,342 | $3,334 |
$2,171
33,196
kWh
|
$171
-
kW-mo/yr
|
- | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $741 | $390 |
$687
10,512
kWh
|
$54
-
kW-mo/yr
|
- | - | |
| 06 | 2.7442: Keep doors and windows shut when not on use | $397 | - |
$357
5,457
kWh
|
$40
-
kW-mo/yr
|
- | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,386 | $4,602 |
$1,137
17,382
kWh
|
$117
-
kW-mo/yr
|
- | $1,132 | |
| 08 | 2.9114: Use solar heat to make electricty | $85,249 | $849,734 |
$81,068
1,239,579
kWh
|
$4,181
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $106,473 | $862,895 |
$91,242
1,395,154
kWh
|
$7,487
-
kW-mo/yr
|
$6,612 | $1,132 | ||
| TOTAL IMPLEMENTED | $5,547 | $8,559 |
$4,337
66,320
kWh
|
$1,210
-
kW-mo/yr
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs