Assessment Year | 1996 |
---|---|
Principal Product | Men's slacks |
NAICS |
n/a
|
SIC | 2325: Men's and Boys' Separate Trousers and Slacks |
Sales Range | $10 M to 50M |
# of Employees | 325 |
Plant Area |
53,000
ft2
|
Annual Production | 1,279,491
pieces
|
Production Hrs. Annual | 2,290
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $150,550 | 1,934,642 |
kWh
|
$0.078 |
Electricity Demand | $91,302 | 6,684 |
kW-mo/yr
|
$13.66 |
Electricity Fees | $684 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $41,683 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $31,923 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 2.2694: Use highest temperature for chilling or cold storage | $7,700 | $60 |
$7,700
96,131
kWh
|
- | - | |
02 | 2.7224: Reduce space conditioning during non-working hours | $5,738 | $250 |
$5,446
181,419
kWh
|
$292
-
kW-mo/yr
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,180 | $2,767 |
$1,930
60,375
kWh
|
$3,250
-
kW-mo/yr
|
- | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,022 | $12,000 |
$3,960
11,137
kWh
|
$62
-
kW-mo/yr
|
- | |
05 | 2.7292: Lower ceiling to reduce conditioned space | $2,738 | $5,000 |
$2,738
91,442
kWh
|
- | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,578 | $12 |
$1,578
49,238
kWh
|
- | - | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $771 | $1,800 |
$234
7,327
kWh
|
$537
-
kW-mo/yr
|
- | |
08 | 2.4133: Use most efficient type of electric motors | $758 | $2,490 |
$394
12,309
kWh
|
$364
-
kW-mo/yr
|
- | |
09 | 2.2692: Use outside cold water source as a supply of cooling water | $491 | $920 |
$491
9,379
kWh
|
- | - | |
10 | 3.5313: Increase amount of waste recovered for resale | $12,707 | $5,023 | - | - |
$12,707
-
lb
|
|
TOTAL RECOMMENDED | $41,683 | $30,322 |
$24,471
518,757
kWh
|
$4,505
-
kW-mo/yr
|
$12,707
-
lb
|
||
TOTAL IMPLEMENTED | $31,923 | $18,072 |
$15,065
326,201
kWh
|
$4,151
-
kW-mo/yr
|
$12,707
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs