| Assessment Year | 1995 |
|---|---|
| Principal Product | Corrugated Board Box |
| NAICS |
n/a
|
| SIC | 2653: Corrugated and Solid Fiber Boxes |
| Sales Range | $10 M to 50M |
| # of Employees | 66 |
| Plant Area |
148,000
ft2
|
| Annual Production | 72,000
thousand feet
|
| Production Hrs. Annual | 2,210
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $38,350 | 560,668 |
kWh
|
$0.068 |
| Natural Gas | $1,488 | 339 |
MMBtu
|
$4.39 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $10,636 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,838 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7261: Install timers and/or thermostats | $2,738 | $1,050 |
$2,738
53,634
kWh
|
|
| 02 | 2.6218: Turn off equipment when not in use | $2,629 | - |
$2,629
18,757
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,216 | $1,102 |
$2,216
34,291
kWh
|
|
| 04 | 2.2694: Use highest temperature for chilling or cold storage | $1,953 | - |
$1,953
38,394
kWh
|
|
| 05 | 2.4133: Use most efficient type of electric motors | $1,100 | $3,090 |
$1,100
18,757
kWh
|
|
| TOTAL RECOMMENDED | $10,636 | $5,242 |
$10,636
163,833
kWh
|
||
| TOTAL IMPLEMENTED | $3,838 | $4,140 |
$3,838
72,391
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs