ITAC Assessment: KG0024
ITAC logo
ITAC Assessment: KG0024
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1995
Principal Product Men's and ladies jeans
NAICS
n/a
SIC 2325: Men's and Boys' Separate Trousers and Slacks
Sales Range $10
M
to 50
M
# of Employees 825
Plant Area 50,000
ft2
Annual Production 5,500,000
units
Production Hrs. Annual 3,720
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $422,133 6,580,891
kWh
Natural Gas $8,748 1,498
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $39,483 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $33,044

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7221: Lower temperature during the winter season and vice-versa $22,550 - $22,550
777,550
kWh
02 2.7142: Utilize higher efficiency lamps and/or ballasts $10,494 $2,725 $10,494
126,612
kWh
03 2.4133: Use most efficient type of electric motors $5,585 $17,170 $5,585
89,390
kWh
04 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $485 $1,470 $485
16,706
kWh
05 2.7135: Install occupancy sensors $369 $130 $369
12,896
kWh
TOTAL RECOMMENDED $39,483 $21,495 $39,483
1,023,154
kWh
TOTAL IMPLEMENTED $33,044 $2,725 $33,044
904,162
kWh
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs