Assessment Year 1994
Principal Product Door Window
NAICS
n/a
SIC 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing
Sales Range $10
M
to 50
M
# of Employees 226
Plant Area 100,380
ft2
Annual Production 21,720
pieces
Production Hrs. Annual 2,125
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $139,943 1,921,747
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $21,029 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $17,756

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.3131: Reschedule plant operations or reduce load to avoid peaks $10,655 $1,260 $10,655
-
kWh
02 2.7142: Utilize higher efficiency lamps and/or ballasts $7,101 $1,382 $7,101
111,079
kWh
03 2.4133: Use most efficient type of electric motors $2,743 $2,890 $2,743
42,204
kWh
04 2.7314: Reduce ventilation air $530 $100 $530
15,240
kWh
TOTAL RECOMMENDED $21,029 $5,632 $21,029
168,523
kWh
TOTAL IMPLEMENTED $17,756 $2,642 $17,756
111,079
kWh
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs