Assessment Year | 1994 |
---|---|
Principal Product | Door Window |
NAICS |
n/a
|
SIC | 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing |
Sales Range | $10 M to 50M |
# of Employees | 226 |
Plant Area |
100,380
ft2
|
Annual Production | 21,720
pieces
|
Production Hrs. Annual | 2,125
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $139,943 | 1,921,747 |
kWh
|
$0.073 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,029 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,756 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $10,655 | $1,260 |
$10,655
-
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,101 | $1,382 |
$7,101
111,079
kWh
|
|
03 | 2.4133: Use most efficient type of electric motors | $2,743 | $2,890 |
$2,743
42,204
kWh
|
|
04 | 2.7314: Reduce ventilation air | $530 | $100 |
$530
15,240
kWh
|
|
TOTAL RECOMMENDED | $21,029 | $5,632 |
$21,029
168,523
kWh
|
||
TOTAL IMPLEMENTED | $17,756 | $2,642 |
$17,756
111,079
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs