Assessment Year 2025
Principal Product N/A
NAICS 813110: Religious Organizations
SIC 8661: Religious Organizations
Sales Range less than $500
k
# of Employees 19
Plant Area 50,000
ft2
Annual Production 1
units
Production Hrs. Annual 3,900
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $20,164 180,209
kWh
Electricity Fees $11,036 -
Natural Gas $10,851 989
MMBtu
TOTAL YEARLY COSTS $42,051
RECOMMENDED SAVINGS* $6,235 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7111: Reduce illumination to minimum necessary levels $715 $77 $715
6,387
kWh
02 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $1,297 $1,750 $1,297
11,579
kWh
03 2.7241: Install outside air damper / economizer on hvac unit $3,551 $11,300 $3,551
31,706
kWh
04 2.7142: Utilize higher efficiency lamps and/or ballasts $672 $3,229 $672
5,998
kWh
TOTAL RECOMMENDED $6,235 $16,356 $6,235
55,670
kWh
TOTAL IMPLEMENTED - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs