Assessment Year | 2024 |
---|---|
Principal Product | Interactive Exhibits |
NAICS | 712110: Museums |
SIC | 8412: Museums and Art Galleries |
Sales Range | $1 M to 5M |
# of Employees | 370 |
Plant Area |
496,000
ft2
|
Annual Production | 370
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $448,112 | 7,281,136 |
kWh
|
$0.062 | |
Electricity Demand | $297,742 | 14,111 |
kW-mo/yr
|
$21.10 | |
Natural Gas | $5,324 | 596 |
MMBtu
|
$8.93 | |
Waste Disposal Costs | |||||
Water Usage | $125,382 | 14,564 |
Tgal
|
$8.61 | |
TOTAL YEARLY COSTS | $876,560 | ||||
RECOMMENDED SAVINGS* | $4,569 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $147 | $14 |
$147
2,447
kWh
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,550 | $3,835 |
$2,396
39,931
kWh
|
$1,154
-
kW-mo/yr
|
|
03 | 2.6127: Maintain air filters by cleaning or replacement | $872 | $1,320 |
$400
6,660
kWh
|
$472
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $4,569 | $5,169 |
$2,943
49,038
kWh
|
$1,626
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs