Assessment Year | 2025 |
---|---|
Principal Product | Medical Device |
NAICS | 327215: Glass Product Manufacturing Made of Purchased Glass |
SIC | 3221: Glass Containers |
Sales Range | $10 M to 50M |
# of Employees | 230 |
Plant Area |
560,000
ft2
|
Annual Production | 1,740,000
pieces
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $597,337 | 11,870,244 |
kWh
|
$0.050 | |
Electricity Demand | $602,322 | 24,713 |
kW-mo/yr
|
$24.37 | |
Electricity Fees | $32,839 | - |
|
- | |
Natural Gas | $45,198 | 5,836 |
MMBtu
|
$7.74 | |
Waste Disposal Costs | |||||
Water Usage | $108,849 | 24,510 |
Tgal
|
$4.44 | |
TOTAL YEARLY COSTS | $1,386,545 | ||||
RECOMMENDED SAVINGS* | $124,294 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7226: Use computer programs to optimize hvac performance | $49,158 | - |
$28,980
579,600
kWh
|
$20,178
-
kW-mo/yr
|
|
02 | 2.4239: Eliminate or reduce compressed air usage | $46,665 | - |
$27,510
550,190
kWh
|
$19,155
-
kW-mo/yr
|
|
03 | 2.2211: Use optimum temperature | $18,398 | - |
$9,040
180,800
kWh
|
$9,358
-
kW-mo/yr
|
|
04 | 2.7135: Install occupancy sensors | $10,073 | $3,780 |
$10,073
201,466
kWh
|
- | |
TOTAL RECOMMENDED | $124,294 | $3,780 |
$75,603
1,512,056
kWh
|
$48,691
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |