Assessment Year 2024
Principal Product Temperature Sensors
NAICS 334519: Other Measuring and Controlling Device Manufacturing
SIC 3823: Industrial Instruments for Measurement, Display, and Control of Process Variables; and Related Products
Sales Range $10
M
to 50
M
# of Employees 205
Plant Area 86,777
ft2
Annual Production 500,000
pieces
Production Hrs. Annual 4,872
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $231,486 2,377,081
kWh
Electricity Demand $48,460 6,655
kW-mo/yr
Electricity Fees $3,400 -
Natural Gas $31,528 3,111
MMBtu
Waste Disposal Costs
Water Usage $7,143 445
Tgal
Water Disposal $12,574 445
Tgal
TOTAL YEARLY COSTS $334,591
RECOMMENDED SAVINGS* $51,014 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $4,623 - $3,608
37,975
kWh
$1,015
-
kW-mo/yr
-
02 2.2211: Use optimum temperature $2,876 - - - $2,876
-
MMBtu
03 2.6211: Conserve energy by efficient use of vending machines $1,317 - $1,186
12,481
kWh
$131
-
kW-mo/yr
-
04 2.7124: Make a practice of turning off lights when not needed $1,154 - $1,154
8,127
kWh
- -
05 2.7221: Lower temperature during the winter season and vice-versa $811 - $92
960
kWh
- $719
-
MMBtu
06 2.4322: Use or replace with energy efficient substitutes $5,093 $391 $4,249
44,725
kWh
$844
-
kW-mo/yr
-
07 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $21,966 $24,200 $17,852
187,916
kWh
$4,114
-
kW-mo/yr
-
08 2.7142: Utilize higher efficiency lamps and/or ballasts $13,174 $16,475 $10,990
115,679
kWh
$2,184
-
kW-mo/yr
-
TOTAL RECOMMENDED $51,014 $41,066 $39,131
407,863
kWh
$8,288
-
kW-mo/yr
$3,595
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs