Assessment Year | 2022 |
---|---|
Principal Product | HVAC Filters |
NAICS | 333413: Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing |
SIC | 3564: Industrial and Commercial Fans and Blowers and Air Purification Equipment |
Sales Range | $100 M to 500M |
# of Employees | 500 |
Plant Area |
600,000
ft2
|
Annual Production | 29,549,288
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $275,472 | 5,805,436 |
kWh
|
$0.047 | |
Electricity Demand | $243,351 | 13,045 |
kW-mo/yr
|
$18.65 | |
Electricity Fees | $7,116 | - |
|
- | |
Natural Gas | $37,185 | 6,029 |
MMBtu
|
$6.17 | |
Waste Disposal Costs | |||||
Water Usage | $8,816 | 1,083 |
Tgal
|
$8.14 | |
TOTAL YEARLY COSTS | $571,940 | ||||
RECOMMENDED SAVINGS* | $29,607 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $29,607 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.6211: Conserve energy by efficient use of vending machines | $1,832 | - |
$1,196
25,453
kWh
|
$636
-
kW-mo/yr
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,118 | - |
$2,296
48,852
kWh
|
$1,822
-
kW-mo/yr
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,553 | $131 |
$3,653
77,727
kWh
|
$2,899
-
kW-mo/yr
|
- | |
04 | 2.7124: Make a practice of turning off lights when not needed | $13,401 | $740 |
$11,716
249,278
kWh
|
$1,684
-
kW-mo/yr
|
- | |
05 | 2.2437: Recover waste heat from equipment | $1,705 | $1,518 |
$(-36.6)
(-780)
kWh
|
$(-28.0)
-
kW-mo/yr
|
$1,770
-
MMBtu
|
|
06 | 2.2437: Recover waste heat from equipment | $1,289 | $1,882 |
$(-36.6)
(-780)
kWh
|
$(-28.0)
-
kW-mo/yr
|
$1,353
-
MMBtu
|
|
07 | 2.7134: Use photocell controls | $152 | $456 |
$131
2,777
kWh
|
$21
-
kW-mo/yr
|
- | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $557 | $2,516 |
$468
9,959
kWh
|
$89
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $29,607 | $7,243 |
$19,387
412,485
kWh
|
$7,096
-
kW-mo/yr
|
$3,123
-
MMBtu
|
||
TOTAL IMPLEMENTED | $29,607 | $7,243 |
$19,387
412,485
kWh
|
$7,096
-
kW-mo/yr
|
$3,123
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs