Assessment Year | 2022 |
---|---|
Principal Product | Waste Water Treatment |
NAICS | 221320: Sewage Treatment Facilities |
SIC | 4952: Sewerage Systems |
Sales Range | $5 M to 10M |
# of Employees | 22 |
Plant Area |
60,000
ft2
|
Annual Production | 2,555,000
Tgal
|
Production Hrs. Annual | 3,484
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $211,635 | 4,402,975 |
kWh
|
$0.048 | |
Electricity Demand | $165,576 | 8,246 |
kW-mo/yr
|
$20.08 | |
Electricity Fees | $708 | - |
|
- | |
Natural Gas | $11,116 | 5,856 |
MMBtu
|
$1.90 | |
Waste Disposal Costs | |||||
Water Usage | $10,800 | 3,000 |
Tgal
|
$3.60 | |
TOTAL YEARLY COSTS | $399,834 | ||||
RECOMMENDED SAVINGS* | $41,194 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7221: Lower temperature during the winter season and vice-versa | $2,018 | $53 |
$168
3,490
kWh
|
- |
$1,851
-
MMBtu
|
|
02 | 2.7135: Install occupancy sensors | $73 | $128 |
$73
1,523
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,112 | $6,705 |
$756
15,745
kWh
|
$1,356
-
kW-mo/yr
|
- | |
04 | 3.7311: Maintain machines to reduce leaks | $36,991 | $130,160 |
$23,516
489,925
kWh
|
$13,475
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $41,194 | $137,046 |
$24,512
510,683
kWh
|
$14,831
-
kW-mo/yr
|
$1,851
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs