Assessment Year | 2020 |
---|---|
Principal Product | Burial Caskets |
NAICS | 339995: Burial Casket Manufacturing |
SIC | 3995: Burial Caskets |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
250,000
ft2
|
Annual Production | 52,000
units
|
Production Hrs. Annual | 5,668
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $262,703 | 2,383,920 |
kWh
|
$0.11 |
Electricity Demand | $55,793 | 9,060 |
kW-mo/yr
|
$6.16 |
Electricity Fees | $228 | - |
|
- |
Natural Gas | $17,052 | 2,078 |
MMBtu
|
$8.21 |
TOTAL YEARLY COSTS | $335,776 | |||
RECOMMENDED SAVINGS* | $128,192 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $90,442 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4322: Use or replace with energy efficient substitutes | $1,243 | - |
$1,157
10,512
kWh
|
$86
-
kW-mo/yr
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,551 | $36 |
$4,551
41,299
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $84,001 | $51,911 |
$75,112
681,593
kWh
|
$8,889
-
kW-mo/yr
|
|
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $647 | $1,350 |
$548
4,975
kWh
|
$99
-
kW-mo/yr
|
|
05 | 2.9114: Use solar heat to make electricty | $37,750 | $333,343 |
$37,750
342,556
kWh
|
- | |
TOTAL RECOMMENDED | $128,192 | $386,640 |
$119,118
1,080,935
kWh
|
$9,074
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $90,442 | $53,297 |
$81,368
738,379
kWh
|
$9,074
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs