| Assessment Year | 2020 |
|---|---|
| Principal Product | Potable Drinking Water |
| NAICS | 221310: Water Supply and Irrigation Systems |
| SIC | 4941: Water Supply |
| Sales Range | $10 M to 50M |
| # of Employees | 5 |
| Plant Area |
530,820
ft2
|
| Annual Production | 4,335,000
Tgal
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $188,631 | 5,419,400 |
kWh
|
$0.035 |
| Electricity Demand | $261,079 | 11,762 |
kW-mo/yr
|
$22.20 |
| Electricity Fees | $(-10,376.0) | - |
|
- |
| Natural Gas | $7,494 | 1,441 |
MMBtu
|
$5.20 |
| TOTAL YEARLY COSTS | $446,828 | |||
| RECOMMENDED SAVINGS* | $31,972 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,106 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7221: Lower temperature during the winter season and vice-versa | $1,050 | $660 | - | - |
$1,050
-
MMBtu
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,106 | $2,237 |
$2,482
71,319
kWh
|
$624
-
kW-mo/yr
|
- | |
| 03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $27,816 | $28,862 |
$32
930
kWh
|
$27,784
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $31,972 | $31,759 |
$2,514
72,249
kWh
|
$28,408
-
kW-mo/yr
|
$1,050
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $3,106 | $2,237 |
$2,482
71,319
kWh
|
$624
-
kW-mo/yr
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs