| Assessment Year | 2019 |
|---|---|
| Principal Product | Furnace Equipment |
| NAICS | 332312: Fabricated Structural Metal Manufacturing |
| SIC | 3441: Fabricated Structural Metal |
| Sales Range | $10 M to 50M |
| # of Employees | 90 |
| Plant Area |
125,200
ft2
|
| Annual Production | 720
units
|
| Production Hrs. Annual | 6,396
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $44,617 | 825,700 |
kWh
|
$0.054 |
| Electricity Demand | $61,156 | 3,267 |
kW-mo/yr
|
$18.72 |
| Electricity Fees | $7,665 | - |
|
- |
| Natural Gas | $44,727 | 7,705 |
MMBtu
|
$5.80 |
| TOTAL YEARLY COSTS | $158,165 | |||
| RECOMMENDED SAVINGS* | $18,647 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,227 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7221: Lower temperature during the winter season and vice-versa | $702 | - |
$702
12,982
kWh
|
- | - | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,930 | $54 |
$1,930
35,710
kWh
|
- | - | |
| 03 | 2.3212: Optimize plant power factor | $9,556 | $3,958 | - | - | $9,556 | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $162 | $63 |
$140
2,587
kWh
|
$22
-
kW-mo/yr
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,297 | $22,990 |
$5,960
110,296
kWh
|
$337
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $18,647 | $27,065 |
$8,732
161,575
kWh
|
$359
-
kW-mo/yr
|
$9,556 | ||
| TOTAL IMPLEMENTED | $8,227 | $23,044 |
$7,890
146,006
kWh
|
$337
-
kW-mo/yr
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs