ITAC Assessment: IP0087
ITAC logo
ITAC Assessment: IP0087
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2017
Principal Product Refined Soybean Oil and Meal
NAICS 311225: Fats and Oils Refining and Blending
SIC 2075: Soybean Oil Mills
Sales Range greater than $500
M
# of Employees 113
Plant Area 5,096,520
ft2
Annual Production 700,000,000
lb
Production Hrs. Annual 8,400
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $3,031,000 62,225,622
kWh
Electricity Demand $1,154,068 100,704
kW-mo/yr
Electricity Fees $46,249 -
Natural Gas $3,423,261 1,173,415
MMBtu
Waste Disposal Costs
Water Usage $153,345 129,827,800
Tgal
Water Disposal $338,922 59,669
Tgal
TOTAL YEARLY COSTS $8,146,845
RECOMMENDED SAVINGS* $677,041 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $63,752

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
01 2.6211: Conserve energy by efficient use of vending machines $1,035 - $783
16,031
kWh
$252
-
kW-mo/yr
- -
02 2.7221: Lower temperature during the winter season and vice-versa $23,755 $72 $11,850
242,822
kWh
- $11,905
-
MMBtu
-
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,755 $189 $1,314
26,929
kWh
$441
-
kW-mo/yr
- -
04 2.7135: Install occupancy sensors $3,851 $308 $3,851
78,909
kWh
- - -
05 2.1233: Analyze flue gas for proper air/fuel ratio $5,139 $432 - - $5,139
-
MMBtu
-
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $21,213 $2,430 $15,884
325,500
kWh
$5,329
-
kW-mo/yr
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $13,313 $7,280 $9,969
204,288
kWh
$3,344
-
kW-mo/yr
- -
08 2.7241: Install outside air damper / economizer on hvac unit $509 $529 $509
10,430
kWh
- - -
09 2.7142: Utilize higher efficiency lamps and/or ballasts $332 $798 $251
5,151
kWh
$81
-
kW-mo/yr
- -
10 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat $606,139 $2,150,000 $798,550
16,363,740
kWh
$267,456
-
kW-mo/yr
$86,829
-
MMBtu
$(-546,696.0)
TOTAL RECOMMENDED $677,041 $2,162,038 $842,961
17,273,800
kWh
$276,903
-
kW-mo/yr
$103,873
-
MMBtu
$(-546,696.0)
TOTAL IMPLEMENTED $63,752 $11,012 $37,954
777,761
kWh
$8,754
-
kW-mo/yr
$17,044
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs