| Assessment Year | 2016 |
|---|---|
| Principal Product | Wire Shelving/ Organizational Boards |
| NAICS | 332618: Other Fabricated Wire Product Manufacturing |
| SIC | 3496: Miscellaneous Fabricated Wire Products |
| Sales Range | $10 M to 50M |
| # of Employees | 75 |
| Plant Area |
630,000
ft2
|
| Annual Production | 10,437,079
pieces
|
| Production Hrs. Annual | 2,100
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $293,383 | 4,170,614 |
kWh
|
$0.070 |
| Electricity Demand | $62,042 | 17,726 |
kW-mo/yr
|
$3.50 |
| Electricity Fees | $9,689 | - |
|
- |
| Natural Gas | $74,239 | 14,437 |
MMBtu
|
$5.14 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $15,489 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $7,105 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 4.454: Modify startup/shutdown times | $2,912 | - | - |
$2,912
-
kW-mo/yr
|
- | |
| 02 | 2.6211: Conserve energy by efficient use of vending machines | $1,741 | - |
$1,630
23,170
kWh
|
$111
-
kW-mo/yr
|
- | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $170 | $5 |
$132
1,883
kWh
|
$38
-
kW-mo/yr
|
- | |
| 04 | 2.6218: Turn off equipment when not in use | $416 | $3 |
$416
5,908
kWh
|
- | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $215 | $36 |
$215
3,061
kWh
|
- | - | |
| 06 | 2.7135: Install occupancy sensors | $2,624 | $683 |
$2,624
37,296
kWh
|
- | - | |
| 07 | 2.2437: Recover waste heat from equipment | $839 | $586 |
$794
11,288
kWh
|
$45
-
kW-mo/yr
|
- | |
| 08 | 2.4322: Use or replace with energy efficient substitutes | $268 | $240 |
$268
3,803
kWh
|
- | - | |
| 09 | 2.7444: Close holes and openings in building such as broken windows | $113 | $112 | - | - |
$113
-
MMBtu
|
|
| 10 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $5,185 | $9,768 | - | - |
$5,185
-
MMBtu
|
|
| 11 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,006 | $2,156 |
$783
11,130
kWh
|
$223
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $15,489 | $13,589 |
$6,862
97,539
kWh
|
$3,329
-
kW-mo/yr
|
$5,298
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $7,105 | $12,080 |
$1,546
21,982
kWh
|
$261
-
kW-mo/yr
|
$5,298
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs