Assessment Year | 2016 |
---|---|
Principal Product | Residential Furnace & fan coils |
NAICS | 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
Sales Range | greater than $500 M |
# of Employees | 500 |
Plant Area |
600,000
ft2
|
Annual Production | 1,600,000
pieces
|
Production Hrs. Annual | 5,052
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,073,115 | 21,498,400 |
kWh
|
$0.050 |
Electricity Demand | $501,315 | 44,684 |
kW-mo/yr
|
$11.22 |
Electricity Fees | $4,433 | - |
|
- |
Natural Gas | $414,338 | 82,985 |
MMBtu
|
$4.99 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $98,481 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,007 | $326 |
$10,007
200,452
kWh
|
- | - | - | - | - | |
02 | 2.7135: Install occupancy sensors | $256 | $51 |
$256
5,138
kWh
|
- | - | - | - | - | |
03 | 2.3192: Use fossil fuel powered generator during peak demand periods | $30,281 | $6,819 |
$624
12,500
kWh
|
$31,820
-
kW-mo/yr
|
- | - | - | $(-2,163.0) | |
04 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $11,137 | $4,626 | - | - | - |
$11,137
-
MMBtu
|
- | - | |
05 | 3.4145: Use magnetic technology to treat water | $227 | $255 | - | - | - | - |
$227
-
Tgal
|
- | |
06 | 2.3212: Optimize plant power factor | $46,574 | $102,745 | - | - | $46,574 | - | - | - | |
TOTAL RECOMMENDED | $98,481 | $114,822 |
$10,887
218,090
kWh
|
$31,820
-
kW-mo/yr
|
$46,574 |
$11,137
-
MMBtu
|
$227
-
Tgal
|
$(-2,163.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs