Assessment Year 2016
Principal Product Residential Furnace & fan coils
NAICS 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen
SIC 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment
Sales Range greater than $500
M
# of Employees 500
Plant Area 600,000
ft2
Annual Production 1,600,000
pieces
Production Hrs. Annual 5,052
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,073,115 21,498,400
kWh
Electricity Demand $501,315 44,684
kW-mo/yr
Electricity Fees $4,433 -
Natural Gas $414,338 82,985
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $98,481 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Water Disposal Savings Ancillary Material Cost Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $10,007 $326 $10,007
200,452
kWh
- - - - -
02 2.7135: Install occupancy sensors $256 $51 $256
5,138
kWh
- - - - -
03 2.3192: Use fossil fuel powered generator during peak demand periods $30,281 $6,819 $624
12,500
kWh
$31,820
-
kW-mo/yr
- - - $(-2,163.0)
04 2.2426: Use waste heat from flue gases to heat space conditioning air $11,137 $4,626 - - - $11,137
-
MMBtu
- -
05 3.4145: Use magnetic technology to treat water $227 $255 - - - - $227
-
Tgal
-
06 2.3212: Optimize plant power factor $46,574 $102,745 - - $46,574 - - -
TOTAL RECOMMENDED $98,481 $114,822 $10,887
218,090
kWh
$31,820
-
kW-mo/yr
$46,574 $11,137
-
MMBtu
$227
-
Tgal
$(-2,163.0)