Assessment Year | 2015 |
---|---|
Principal Product | Transmission Seals |
NAICS | 339991: Gasket, Packing, and Sealing Device Manufacturing |
SIC | 3053: Gaskets, Packing, and Sealing Devices |
Sales Range | $50 M to 100M |
# of Employees | 493 |
Plant Area |
185,000
ft2
|
Annual Production | 24,637,577
pieces
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $918,629 | 27,846,000 |
kWh
|
$0.033 |
Electricity Demand | $897,489 | 48,266 |
kW-mo/yr
|
$18.59 |
Natural Gas | $254,073 | 42,066 |
MMBtu
|
$6.04 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $184,342 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,180 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 3.8132: Use less toxic and volatile solvent substitutes | $37,208 | - | - | - | - | - | - | $37,208 | |
02 | 4.812: Apply for investment incentives | $1,728 | - | - | - | $1,728 | - | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,452 | $99 |
$3,452
104,599
kWh
|
- | - | - | - | - | |
04 | 3.5242: Recover metals from spent solutions and recycle | $104,502 | $3,200 | - | - | - | - |
$104,502
-
lb
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $168 | $8 |
$88
2,673
kWh
|
$80
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.2531: Re-size charging openings or add movable cover or door | $896 | $212 | - | - | - |
$896
-
MMBtu
|
- | - | |
07 | 2.7135: Install occupancy sensors | $430 | $130 |
$430
13,029
kWh
|
- | - | - | - | - | |
08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $18,251 | $12,039 |
$18,251
553,059
kWh
|
- | - | - | - | - | |
09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $15,775 | $32,120 |
$15,775
478,023
kWh
|
- | - | - | - | - | |
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $634 | $1,321 |
$333
10,092
kWh
|
$301
-
kW-mo/yr
|
- | - | - | - | |
11 | 2.2531: Re-size charging openings or add movable cover or door | $1,298 | $3,968 |
$1,298
39,344
kWh
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $184,342 | $53,097 |
$39,627
1,200,819
kWh
|
$381
-
kW-mo/yr
|
$1,728 |
$896
-
MMBtu
|
$104,502
-
lb
|
$37,208 | ||
TOTAL IMPLEMENTED | $5,180 | $99 |
$3,452
104,599
kWh
|
- | $1,728 | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs