Assessment Year | 2015 |
---|---|
Principal Product | Hospitality and Dorm Furniture |
NAICS | 337122: Nonupholstered Wood Household Furniture Manufacturing |
SIC | 2511: Wood Household Furniture, Except Upholstered |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
196,100
ft2
|
Annual Production | 233,000
pieces
|
Production Hrs. Annual | 2,613
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $238,489 | 2,799,600 |
kWh
|
$0.085 |
Electricity Demand | $45,154 | 12,706 |
kW-mo/yr
|
$3.55 |
Electricity Fees | $9,637 | - |
|
- |
Natural Gas | $140,919 | 15,100 |
MMBtu
|
$9.33 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $81,636 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $66,373 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Wood Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 4.812: Apply for investment incentives | $2,707 | - | - | - | $2,707 | - | - | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $267 | - |
$224
2,634
kWh
|
$43
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.7221: Lower temperature during the winter season and vice-versa | $14,074 | $227 | - | - | - |
$14,074
-
MMBtu
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,417 | $113 |
$4,417
51,856
kWh
|
- | - | - | - | - | |
05 | 2.243: Heat recovery from specific equipment | $1,364 | $171 | - | - | - |
$1,364
-
MMBtu
|
- | - | |
06 | 2.2511: Insulate bare equipment | $1,469 | $211 | - | - | - |
$1,469
-
MMBtu
|
- | - | |
07 | 2.4322: Use or replace with energy efficient substitutes | $4,192 | $980 |
$4,192
49,262
kWh
|
- | - | - | - | - | |
08 | 2.1332: Convert combustion equipment to burn natural gas | $32,642 | $7,996 | - | - | - |
$(-27,358.0)
-
MMBtu
|
$25,000
-
MMBtu
|
$35,000 | |
09 | 2.2437: Recover waste heat from equipment | $3,490 | $1,421 |
$(-2.0)
(-24)
kWh
|
- | - |
$3,492
-
MMBtu
|
- | - | |
10 | 2.7135: Install occupancy sensors | $518 | $739 |
$518
6,078
kWh
|
- | - | - | - | - | |
11 | 2.2533: Replace air curtain doors with solid doors | $12,533 | $21,055 | - | - | - |
$12,533
-
MMBtu
|
- | - | |
12 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,962 | $9,239 |
$3,326
39,080
kWh
|
$636
-
kW-mo/yr
|
- | - | - | - | |
TOTAL RECOMMENDED | $81,636 | $42,152 |
$12,675
148,886
kWh
|
$679
-
kW-mo/yr
|
$2,707 |
$5,575
-
MMBtu
|
$25,000
-
MMBtu
|
$35,000 | ||
TOTAL IMPLEMENTED | $66,373 | $29,391 |
$4,417
51,856
kWh
|
- | $2,707 |
$(-751.0)
-
MMBtu
|
$25,000
-
MMBtu
|
$35,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Wood Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs