ITAC Assessment: IP0012
ITAC logo
ITAC Assessment: IP0012
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2013
Principal Product Lithium Ion Cells, Modules, Packs, Systems and Battery
NAICS 335912: Primary Battery Manufacturing
SIC 3692: Primary Batteries, Dry and Wet
Sales Range $10
M
to 50
M
# of Employees 75
Plant Area 220,000
ft2
Annual Production 615
pieces
Production Hrs. Annual 2,000
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $175,566 3,033,820
kWh
Electricity Demand $76,839 7,889
kW-mo/yr
Electricity Fees $4,681 -
Natural Gas $87,202 11,553
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $67,318 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $31,787

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.7221: Lower temperature during the winter season and vice-versa $21,525 - $1,984
34,095
kWh
- $19,541
-
MMBtu
02 2.6218: Turn off equipment when not in use $5,948 - $5,948
102,346
kWh
- -
03 2.4231: Reduce the pressure of compressed air to the minimum required $1,627 - $1,325
22,776
kWh
$302
-
kW-mo/yr
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,371 - $1,371
23,568
kWh
- -
05 2.2437: Recover waste heat from equipment $1,316 $1,171 - - $1,316
-
MMBtu
06 2.7135: Install occupancy sensors $2,095 $4,480 $1,043
17,920
kWh
$1,052
-
kW-mo/yr
-
07 2.7313: Recycle air for heating, ventilation and air conditioning $33,436 $104,600 $21,861
375,691
kWh
$3,959
-
kW-mo/yr
$7,616
-
MMBtu
TOTAL RECOMMENDED $67,318 $110,251 $33,532
576,396
kWh
$5,313
-
kW-mo/yr
$28,473
-
MMBtu
TOTAL IMPLEMENTED $31,787 $1,171 $10,628
182,785
kWh
$302
-
kW-mo/yr
$20,857
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs