Assessment Year 2026
Principal Product Office Space
NAICS 551114: Corporate, Subsidiary, and Regional Managing Offices
SIC 6541: Title Abstract Offices
Sales Range less than $500
k
# of Employees 300
Plant Area 205,259
ft2
Annual Production 1
units
Production Hrs. Annual 2,860
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $293,841 2,961,504
kWh
Electricity Demand $76,606 6,037
kW-mo/yr
Electricity Fees $(-3,299.0) -
Natural Gas $40,537 13,678
MMBtu
Other Gas $7,203 1
MMBtu
TOTAL YEARLY COSTS $414,888
RECOMMENDED SAVINGS* $125,648 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.9114: Use solar heat to make electricty $25,993 $124,017 $14,695
148,433
kWh
$11,298
-
kW-mo/yr
-
02 2.6211: Conserve energy by efficient use of vending machines $277 $1,446 $277
2,797
kWh
- -
03 2.4239: Eliminate or reduce compressed air usage $349 $488 $231
2,334
kWh
$118
-
kW-mo/yr
-
04 2.7135: Install occupancy sensors $29,539 $34,882 $23,563
238,013
kWh
$5,976
-
kW-mo/yr
-
05 2.1233: Analyze flue gas for proper air/fuel ratio $1,156 $5,700 - - $1,156
-
MMBtu
06 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $8,902 $39,465 $6,995
70,658
kWh
$1,906
-
kW-mo/yr
-
07 2.2113: Repair or replace steam traps $12,735 $24,175 - - $12,735
-
MMBtu
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,343 $690 $1,120
11,316
kWh
$223
-
kW-mo/yr
-
09 2.7142: Utilize higher efficiency lamps and/or ballasts $45,263 $253,281 $35,213
355,684
kWh
$11,573
-
kW-mo/yr
$(-1,522.8)
-
MMBtu
10 3.4151: Minimize water usage $92 $541 $83
838
kWh
$1
-
kW-mo/yr
$8
-
MMBtu
TOTAL RECOMMENDED $125,648 $484,685 $82,177
830,073
kWh
$31,096
-
kW-mo/yr
$12,375
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs