| Assessment Year | 2026 |
|---|---|
| Principal Product | Heat Treatment/Bar Processing |
| NAICS | 332811: Metal Heat Treating |
| SIC | 3398: Metal Heat Treating |
| Sales Range | $1 M to 5M |
| # of Employees | 34 |
| Plant Area |
255,000
ft2
|
| Annual Production | 2,600
ton
|
| Production Hrs. Annual | 4,992
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $241,838 | 2,669,008 |
kWh
|
$0.091 |
| Electricity Demand | $175,594 | 10,110 |
kW-mo/yr
|
$17.37 |
| Electricity Fees | $57,873 | - |
|
- |
| Natural Gas | $413,450 | 96,365 |
MMBtu
|
$4.29 |
| Other Gas | $129,352 | 1 |
MMBtu
|
$129,352.36 |
| TOTAL YEARLY COSTS | $1,018,108 | |||
| RECOMMENDED SAVINGS* | $91,136 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $30,000 | $112,624 | - |
$30,000
-
kW-mo/yr
|
- | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $629 | $2,060 |
$460
5,059
kWh
|
$169
-
kW-mo/yr
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $540 | $282 |
$376
4,133
kWh
|
$164
-
kW-mo/yr
|
- | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $445 | $760 |
$245
2,688
kWh
|
$201
-
kW-mo/yr
|
- | |
| 05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $45,344 | $21,031 |
$31,082
341,565
kWh
|
$14,262
-
kW-mo/yr
|
- | |
| 06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,850 | $26,620 |
$4,430
48,684
kWh
|
$1,419
-
kW-mo/yr
|
- | |
| 07 | 2.1121: Use insulation in furnaces to facilitate heating / cooling | $5,148 | $20,800 | - | - |
$5,148
-
MMBtu
|
|
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,180 | $732 |
$2,167
23,822
kWh
|
$1,013
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $91,136 | $184,909 |
$38,761
425,952
kWh
|
$47,228
-
kW-mo/yr
|
$5,148
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs