Assessment Year | 2024 |
---|---|
Principal Product | Fruit Juices |
NAICS | 311411: Frozen Fruit, Juice, and Vegetable Manufacturing |
SIC | 2037: Frozen Fruits, Fruit Juices, and Vegetables |
Sales Range | $100 M to 500M |
# of Employees | 140 |
Plant Area |
155,300
ft2
|
Annual Production | 3,997,011
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $565,178 | 9,567,939 |
kWh
|
$0.059 | |
Electricity Demand | $175,934 | 17,350 |
kW-mo/yr
|
$10.14 | |
Electricity Fees | $285,204 | - |
|
- | |
Natural Gas | $109,397 | 15,676 |
MMBtu
|
$6.98 | |
Waste Disposal Costs | |||||
Water Usage | $279,952 | 58,214,000 |
Tgal
|
$0.005 | |
Other Liquid (non-haz) | $106,652 | 22,549,000,000 |
gal
|
$0.000 | |
TOTAL YEARLY COSTS | $1,522,317 | ||||
RECOMMENDED SAVINGS* | $436,440 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $13,108 | - |
$10,610
179,834
kWh
|
$2,498
-
kW-mo/yr
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $577 | $976 |
$471
7,990
kWh
|
$105
-
kW-mo/yr
|
- | |
03 | 2.9114: Use solar heat to make electricty | $335,865 | $2,216,227 |
$165,382
2,803,084
kWh
|
$170,483
-
kW-mo/yr
|
- | |
04 | 2.4133: Use most efficient type of electric motors | $5,880 | $3,863 |
$4,759
80,658
kWh
|
$1,121
-
kW-mo/yr
|
- | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $24,066 | $4,623 |
$21,531
364,935
kWh
|
$2,535
-
kW-mo/yr
|
- | |
06 | 2.4239: Eliminate or reduce compressed air usage | $6,094 | $4,720 |
$4,888
82,844
kWh
|
$1,207
-
kW-mo/yr
|
- | |
07 | 2.3132: Recharge batteries on during off-peak demand periods | $5,023 | - | - |
$5,023
-
kW-mo/yr
|
- | |
08 | 2.4239: Eliminate or reduce compressed air usage | $13,654 | $250 |
$86
1,465
kWh
|
$13,567
-
kW-mo/yr
|
- | |
09 | 2.2511: Insulate bare equipment | $32,173 | $3,405 |
$15,412
261,223
kWh
|
$13,435
-
kW-mo/yr
|
$3,326
-
MMBtu
|
|
TOTAL RECOMMENDED | $436,440 | $2,234,064 |
$223,140
3,782,033
kWh
|
$209,974
-
kW-mo/yr
|
$3,326
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs