Assessment Year | 2023 |
---|---|
Principal Product | Plastic Closures |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 78 |
Plant Area |
160,000
ft2
|
Annual Production | 405,052
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $562,305 | 9,893,214 |
kWh
|
$0.057 |
Electricity Demand | $107,394 | 18,878 |
kW-mo/yr
|
$5.69 |
Electricity Fees | $6,511 | - |
|
- |
Natural Gas | $314 | 16 |
MMBtu
|
$20.25 |
TOTAL YEARLY COSTS | $676,523 | |||
RECOMMENDED SAVINGS* | $200,360 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $28,954 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7221: Lower temperature during the winter season and vice-versa | $434 | - |
$382
6,698
kWh
|
$52
-
kW-mo/yr
|
|
02 | 2.4239: Eliminate or reduce compressed air usage | $6,518 | $9,738 |
$5,716
100,275
kWh
|
$803
-
kW-mo/yr
|
|
03 | 2.4133: Use most efficient type of electric motors | $2,811 | $17,313 |
$2,460
43,156
kWh
|
$351
-
kW-mo/yr
|
|
04 | 2.9114: Use solar heat to make electricty | $130,075 | $1,202,972 |
$82,848
1,453,482
kWh
|
$47,227
-
kW-mo/yr
|
|
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $17,838 | - |
$15,612
273,895
kWh
|
$2,226
-
kW-mo/yr
|
|
06 | 2.3132: Recharge batteries on during off-peak demand periods | $2,786 | - | - |
$2,786
-
kW-mo/yr
|
|
07 | 2.2511: Insulate bare equipment | $19,216 | $10,388 |
$19,216
337,125
kWh
|
- | |
08 | 2.7232: Replace existing hvac unit with high efficiency model | $20,681 | $163,749 |
$19,936
349,754
kWh
|
$745
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $200,360 | $1,404,161 |
$146,170
2,564,385
kWh
|
$54,190
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $28,954 | $20,126 |
$25,313
444,098
kWh
|
$3,640
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs