Assessment Year | 2023 |
---|---|
Principal Product | Thermoforming Products for Electronics, healthcare, food, and industrial purposes |
NAICS | 326113: Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing |
SIC | 3081: Unsupported Plastics Film and Sheet |
Sales Range | $5 M to 10M |
# of Employees | 56 |
Plant Area |
27,000
ft2
|
Annual Production | 332,179
lb
|
Production Hrs. Annual | 4,576
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $27,908 | 633,840 |
kWh
|
$0.044 | |
Electricity Demand | $22,212 | 1,364 |
kW-mo/yr
|
$16.28 | |
Electricity Fees | $17,863 | - |
|
- | |
Natural Gas | $7,821 | 542 |
MMBtu
|
$14.42 | |
Waste Disposal Costs | |||||
Water Usage | $2,882 | 162 |
Tgal
|
$17.84 | |
TOTAL YEARLY COSTS | $78,685 | ||||
RECOMMENDED SAVINGS* | $127,731 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $12,982 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,197 | $3,250 |
$2,638
59,944
kWh
|
$2,560
-
kW-mo/yr
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,536 | $7,857 |
$3,319
75,430
kWh
|
$3,217
-
kW-mo/yr
|
|
03 | 2.7135: Install occupancy sensors | $1,249 | $804 |
$1,066
24,227
kWh
|
$183
-
kW-mo/yr
|
|
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,327 | $2,879 |
$1,232
28,001
kWh
|
$95
-
kW-mo/yr
|
|
05 | 2.9114: Use solar heat to make electricty | $109,160 | $660,787 |
$33,928
771,092
kWh
|
$75,232
-
kW-mo/yr
|
|
06 | 2.7232: Replace existing hvac unit with high efficiency model | $4,262 | $5,407 |
$1,677
38,102
kWh
|
$2,585
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $127,731 | $680,984 |
$43,859
996,796
kWh
|
$83,872
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $12,982 | $11,911 |
$7,023
159,601
kWh
|
$5,960
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs