| Assessment Year | 2022 |
|---|---|
| Principal Product | Farm Machinery and Equipment |
| NAICS | 333111: Farm Machinery and Equipment Manufacturing |
| SIC | 3523: Farm Machinery and Equipment |
| Sales Range | $100 M to 500M |
| # of Employees | 145 |
| Plant Area |
273,500
ft2
|
| Annual Production | 6,700
ton
|
| Production Hrs. Annual | 4,225
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $126,811 | 2,605,907 |
kWh
|
$0.049 |
| Electricity Demand | $89,044 | 15,635 |
kW-mo/yr
|
$5.70 |
| Natural Gas | $23,533 | 31,507 |
MMBtu
|
$0.75 |
| TOTAL YEARLY COSTS | $239,388 | |||
| RECOMMENDED SAVINGS* | $9,034 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,327 | $4,150 |
$5,508
112,400
kWh
|
$1,819
-
kW-mo/yr
|
|
| 02 | 2.7311: Ventilation system to shut off when room is not in use | $356 | $5,338 |
$356
7,274
kWh
|
- | |
| 03 | 2.4322: Use or replace with energy efficient substitutes | $1,351 | $33,110 |
$933
19,048
kWh
|
$418
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $9,034 | $42,598 |
$6,797
138,722
kWh
|
$2,237
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs