Assessment Year | 2022 |
---|---|
Principal Product | Sporting Goods |
NAICS | 451110: Sporting Goods Stores |
SIC | 5941: Sporting Goods Stores and Bicycle Shops |
Sales Range | $50 M to 100M |
# of Employees | 60 |
Plant Area |
133,000
ft2
|
Annual Production | 10,000
units
|
Production Hrs. Annual | 4,380
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $195,171 | 2,242,522 |
kWh
|
$0.087 | |
Natural Gas | $11,966 | 1,802 |
MMBtu
|
$6.64 | |
Waste Disposal Costs | |||||
Water Usage | $13,469 | 973 |
Tgal
|
$13.84 | |
TOTAL YEARLY COSTS | $220,606 | ||||
RECOMMENDED SAVINGS* | $47,651 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $46,632 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,027 | $50 |
$1,027
11,802
kWh
|
|
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,019 | $1,884 |
$1,019
11,714
kWh
|
|
03 | 2.7311: Ventilation system to shut off when room is not in use | $29,987 | $81,889 |
$29,987
344,678
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,023 | $15,042 |
$14,023
161,190
kWh
|
|
05 | 2.7492: Use proper thickness of insulation on building envelope | $210 | $216 |
$210
2,414
kWh
|
|
06 | 2.7135: Install occupancy sensors | $1,385 | $193 |
$1,385
15,925
kWh
|
|
TOTAL RECOMMENDED | $47,651 | $99,274 |
$47,651
547,723
kWh
|
||
TOTAL IMPLEMENTED | $46,632 | $97,390 |
$46,632
536,009
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs