Assessment Year 2010
Principal Product Plastic Bottles
NAICS 326160: Plastics Bottle Manufacturing
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 34
Plant Area 55,000
ft2
Annual Production 126,000,000
pieces
Production Hrs. Annual 6,000
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $674,653 9,290,085
kWh
Electricity Demand $108,175 19,231
kW-mo/yr
Natural Gas $20,506 2,915
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $14,915 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $11,278

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $376 $814 $288
3,935
kWh
$46
-
kW-mo/yr
$25 $17
02 2.7142: Utilize higher efficiency lamps and/or ballasts $2,095 - $1,566
21,451
kWh
$295
-
kW-mo/yr
- $234
03 2.7135: Install occupancy sensors $414 $1,176 $356
4,881
kWh
$58
-
kW-mo/yr
- -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $85 $68 $34
463
kWh
- $34 $17
05 2.7142: Utilize higher efficiency lamps and/or ballasts $245 $62 $118
1,622
kWh
$40
-
kW-mo/yr
$3 $84
06 2.7124: Make a practice of turning off lights when not needed $56 - $50
691
kWh
$6
-
kW-mo/yr
- -
07 2.4133: Use most efficient type of electric motors $5,115 $12,247 $4,411
60,410
kWh
$704
-
kW-mo/yr
- -
08 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,084 $1,150 $4,084
55,950
kWh
- - -
09 2.4235: Remove or close off unneeded compressed air lines $916 - $916
12,533
kWh
- - -
10 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,297 $84 $80
1,100
kWh
$1,217
-
kW-mo/yr
- -
11 2.6211: Conserve energy by efficient use of vending machines $232 - $131
1,800
kWh
$101
-
kW-mo/yr
- -
TOTAL RECOMMENDED $14,915 $15,601 $12,034
164,836
kWh
$2,467
-
kW-mo/yr
$62 $352
TOTAL IMPLEMENTED $11,278 $15,455 $10,270
140,663
kWh
$915
-
kW-mo/yr
$59 $34
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs