| Assessment Year | 2009 |
|---|---|
| Principal Product | Architectural Paint Colorant |
| NAICS | 325510: Paint and Coating Manufacturing |
| SIC | 2851: Paints, Varnishes, Lacquers, Enamels, and Allied Products |
| Sales Range | $100 M to 500M |
| # of Employees | 206 |
| Plant Area |
154,800
ft2
|
| Annual Production | 3,000
Tgal
|
| Production Hrs. Annual | 8,520
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $496,091 | 7,054,518 |
kWh
|
$0.070 |
| Electricity Demand | $93,969 | 18,921 |
kW-mo/yr
|
$4.97 |
| Electricity Fees | $9,018 | - |
|
- |
| Natural Gas | $254,042 | 26,485 |
MMBtu
|
$9.59 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $63,943 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $48,743 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,382 | $22,982 |
$8,350
119,323
kWh
|
$1,003
-
kW-mo/yr
|
$2,234 | - | $(-205.0) | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,659 | $1,839 |
$903
12,855
kWh
|
$205
-
kW-mo/yr
|
$551 | - | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,541 | $54,496 |
$13,897
198,525
kWh
|
$1,551
-
kW-mo/yr
|
$(-3,439.0) | $1,532 | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,295 | $1,754 |
$1,246
17,801
kWh
|
$119
-
kW-mo/yr
|
$3,250 | - | $680 | |
| 05 | 2.4133: Use most efficient type of electric motors | $14,810 | $35,989 |
$12,878
183,974
kWh
|
$1,932
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $11,070 | $2,415 |
$11,070
158,139
kWh
|
- | - | - | - | |
| 07 | 2.6211: Conserve energy by efficient use of vending machines | $646 | - |
$378
5,400
kWh
|
$268
-
kW-mo/yr
|
- | - | - | |
| 08 | 2.2437: Recover waste heat from equipment | $5,540 | $823 |
$5,540
573
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $63,943 | $120,298 |
$54,262
696,590
kWh
|
$5,078
-
kW-mo/yr
|
$2,596 | $1,532 | $475 | ||
| TOTAL IMPLEMENTED | $48,743 | $63,963 |
$39,462
485,210
kWh
|
$3,322
-
kW-mo/yr
|
$5,484 | - | $475 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs