Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $823,864 | 18,833,577 |
kWh
|
$0.044 |
Electricity Demand | $432,021 | 38,168 |
kW-mo/yr
|
$11.32 |
Natural Gas | $1,102,005 | 114,697 |
MMBtu
|
$9.61 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $1,889 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $1,078 | $642 |
$659
14,976
kWh
|
$419
-
kW-mo/yr
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $206 | - |
$206
4,676
kWh
|
- | - | |
03 | 2.9112: Use solar heat to heat water | $605 | $2,240 | - | - |
$605
-
MMBtu
|
|
TOTAL RECOMMENDED | $1,889 | $2,882 |
$865
19,652
kWh
|
$419
-
kW-mo/yr
|
$605
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs