Assessment Year | 2008 |
---|---|
Principal Product | plasitc parts of appliances |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 50 |
Plant Area |
46,598
ft2
|
Annual Production | 6,500,000
pieces
|
Production Hrs. Annual | 6,072
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $96,648 | 1,906,200 |
kWh
|
$0.051 |
Electricity Demand | $62,368 | 10,893 |
kW-mo/yr
|
$5.73 |
Electricity Fees | $1,694 | - |
|
- |
Natural Gas | $11,249 | 998 |
MMBtu
|
$11.27 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,848 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,110 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,805 | $14,430 |
$4,683
91,814
kWh
|
$1,043
-
kW-mo/yr
|
- | $23 | $56 | |
02 | 2.7122: Disconnect ballasts | $26 | $26 |
$20
399
kWh
|
$6
-
kW-mo/yr
|
- | - | - | |
03 | 2.7124: Make a practice of turning off lights when not needed | $338 | - |
$207
4,075
kWh
|
$131
-
kW-mo/yr
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $944 | $162 |
$410
8,033
kWh
|
$92
-
kW-mo/yr
|
- | - | $442 | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $90 | $142 |
$39
771
kWh
|
$6
-
kW-mo/yr
|
- | - | $45 | |
06 | 2.4133: Use most efficient type of electric motors | $1,385 | $1,541 |
$1,208
23,678
kWh
|
$177
-
kW-mo/yr
|
- | - | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,544 | $1,035 |
$5,544
108,710
kWh
|
- | - | - | - | |
08 | 2.2511: Insulate bare equipment | $688 | $580 |
$471
9,207
kWh
|
$217
-
kW-mo/yr
|
- | - | - | |
09 | 2.1135: Repair furnaces and oven doors so that they seal efficiently | $1,040 | $37 |
$1,040
20,398
kWh
|
- | - | - | - | |
10 | 2.2511: Insulate bare equipment | $50 | $42 |
$50
982
kWh
|
- | - | - | - | |
11 | 2.2622: Replace existing chiller with high efficiency model | $6,202 | $32,361 |
$5,102
100,046
kWh
|
$1,100
-
kW-mo/yr
|
- | - | - | |
12 | 2.7224: Reduce space conditioning during non-working hours | $541 | - | - | - |
$541
-
MMBtu
|
- | - | |
13 | 2.6211: Conserve energy by efficient use of vending machines | $195 | - |
$92
1,800
kWh
|
$103
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $22,848 | $50,356 |
$18,866
369,913
kWh
|
$2,875
-
kW-mo/yr
|
$541
-
MMBtu
|
$23 | $543 | ||
TOTAL IMPLEMENTED | $16,110 | $35,304 |
$13,570
266,110
kWh
|
$1,512
-
kW-mo/yr
|
$541
-
MMBtu
|
- | $487 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs