Assessment Year | 2007 |
---|---|
Principal Product | Architectural Glass |
NAICS | 327215: Glass Product Manufacturing Made of Purchased Glass |
SIC | 3231: Glass Products, Made of Purchased Glass |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
87,150
ft2
|
Annual Production | 260
thousand feet
|
Production Hrs. Annual | 6,552
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $50,799 | 711,858 |
kWh
|
$0.071 |
Electricity Demand | $25,008 | 4,322 |
kW-mo/yr
|
$5.79 |
Natural Gas | $124,177 | 10,853 |
MMBtu
|
$11.44 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $33,702 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.5111: Convert from indirect to direct fired systems | $12,768 | $40,352 | - | - |
$12,768
-
MMBtu
|
- | - | - | |
02 | 2.2136: Install / repair insulation on steam lines | $1,486 | $1,890 | - | - |
$1,486
-
MMBtu
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,652 | $21,323 |
$2,600
38,239
kWh
|
$846
-
kW-mo/yr
|
- | $67 | - | $139 | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,983 | $790 |
$1,937
28,490
kWh
|
$46
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,094 | $1,096 |
$803
11,806
kWh
|
$261
-
kW-mo/yr
|
- | - | - | $30 | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $36 | $128 |
$19
273
kWh
|
$11
-
kW-mo/yr
|
- | $13 | - | $(-7.0) | |
07 | 2.4322: Use or replace with energy efficient substitutes | $2,363 | $231 |
$1,871
27,504
kWh
|
$492
-
kW-mo/yr
|
- | - | - | - | |
08 | 2.4323: Use optimum size and capacity equipment | $1,216 | $5,830 |
$1,216
17,888
kWh
|
- | - | - | - | - | |
09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $499 | $684 |
$499
7,340
kWh
|
- | - | - | - | - | |
10 | 2.4133: Use most efficient type of electric motors | $2,396 | $8,878 |
$1,875
27,571
kWh
|
$521
-
kW-mo/yr
|
- | - | - | - | |
11 | 2.8114: Change rate schedules or other changes in utility service | $6,209 | - | - | - | - | - | $6,209 | - | |
TOTAL RECOMMENDED | $33,702 | $81,202 |
$10,820
159,111
kWh
|
$2,177
-
kW-mo/yr
|
$14,254
-
MMBtu
|
$80 | $6,209 | $162 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs