Assessment Year | 2006 |
---|---|
Principal Product | bakery ingredients |
NAICS | 311812: Commercial Bakeries |
SIC | 2051: Bread and Other Bakery Products, Except Cookies and Crackers |
Sales Range | $50 M to 100M |
# of Employees | 95 |
Plant Area |
167,700
ft2
|
Annual Production | 70,000,000
lb
|
Production Hrs. Annual | 4,040
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $113,859 | 2,989,540 |
kWh
|
$0.038 |
Electricity Demand | $81,266 | 6,642 |
kW-mo/yr
|
$12.24 |
Electricity Fees | $1,317 | - |
|
- |
Natural Gas | $530,499 | 57,235 |
MMBtu
|
$9.27 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $88,038 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $24,650 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.2136: Install / repair insulation on steam lines | $17,152 | $4,984 | - | - |
$17,152
-
MMBtu
|
- | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,664 | $700 |
$2,664
70,119
kWh
|
- | - | - | - | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $8,928 | $9,302 |
$2,695
70,935
kWh
|
$6,233
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.1222: Install turbulators | $7,715 | $23,253 | - | - |
$7,715
-
MMBtu
|
- | - | - | |
05 | 2.7232: Replace existing hvac unit with high efficiency model | $20,185 | $115,000 |
$(-3,403.0)
(-89,544)
kWh
|
$(-3,023.0)
-
kW-mo/yr
|
$26,611
-
MMBtu
|
- | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $440 | $1,664 |
$110
2,891
kWh
|
$48
-
kW-mo/yr
|
- | $103 | $179 | - | |
07 | 2.2121: Increase amount of condensate returned | $18,627 | $88,113 | - | - |
$8,935
-
MMBtu
|
- | - |
$9,692
-
Tgal
|
|
08 | 2.4133: Use most efficient type of electric motors | $4,394 | $27,491 |
$2,329
61,266
kWh
|
$2,065
-
kW-mo/yr
|
- | - | - | - | |
09 | 2.2622: Replace existing chiller with high efficiency model | $7,933 | $89,400 |
$3,203
84,298
kWh
|
$2,730
-
kW-mo/yr
|
- | $2,000 | - | - | |
TOTAL RECOMMENDED | $88,038 | $359,907 |
$7,598
199,965
kWh
|
$8,053
-
kW-mo/yr
|
$60,413
-
MMBtu
|
$2,103 | $179 |
$9,692
-
Tgal
|
||
TOTAL IMPLEMENTED | $24,650 | $34,839 |
$5,103
134,276
kWh
|
$2,113
-
kW-mo/yr
|
$17,152
-
MMBtu
|
$103 | $179 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs