Assessment Year 2004
Principal Product Powdered Metal Parts
NAICS 332215: Metal Kitchen Cookware, Utensil, Cutlery, and Flatware (except Precious) Manufacturing
SIC 3499: Fabricated Metal Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 200
Plant Area 110,000
ft2
Annual Production 7,000,000
lb
Production Hrs. Annual 6,874
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $699,271 27,900,000
kWh
Electricity Demand $422,203 60,348
kW-mo/yr
Electricity Fees $37,881 -
Natural Gas $75,780 98,353
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $40,574 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $24,437

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.1113: Reduce combustion air flow to optimum $17,317 - - - $17,317
-
MMBtu
- -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,918 $300 $2,918
56,408
kWh
$1,000
-
kW-mo/yr
- - -
03 2.4231: Reduce the pressure of compressed air to the minimum required $6,932 $425 $5,144
98,714
kWh
$1,788
-
kW-mo/yr
- - -
04 2.4239: Eliminate or reduce compressed air usage $2,643 $9,400 $1,966
37,903
kWh
$677
-
kW-mo/yr
- - -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $559 $77 $418
8,143
kWh
$141
-
kW-mo/yr
- - -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $9,205 $30,427 $5,847
73,236
kWh
$1,736
-
kW-mo/yr
- $332 $1,290
TOTAL RECOMMENDED $40,574 $40,629 $16,293
274,404
kWh
$5,342
-
kW-mo/yr
$17,317
-
MMBtu
$332 $1,290
TOTAL IMPLEMENTED $24,437 $9,777 $5,302
102,454
kWh
$1,818
-
kW-mo/yr
$17,317
-
MMBtu
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs