Assessment Year | 2004 |
---|---|
Principal Product | Prepared Metal Products |
NAICS | 311613: Rendering and Meat Byproduct Processing |
SIC | 2013: Sausages and Other Prepared Meat Products |
Sales Range | $50 M to 100M |
# of Employees | 175 |
Plant Area |
53,860
ft2
|
Annual Production | 18,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $133,007 | 3,410,412 |
kWh
|
$0.039 |
Electricity Demand | $26,396 | 6,959 |
kW-mo/yr
|
$3.79 |
Electricity Fees | $23,854 | - |
|
- |
Natural Gas | $26,250 | 3,722 |
MMBtu
|
$7.05 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $24,781 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,036 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $599 | - | - | - |
$599
-
MMBtu
|
- | - | |
02 | 2.6232: Install set-back timers | $2,895 | $159 | - | - |
$2,895
-
MMBtu
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,195 | $600 |
$1,076
16,292
kWh
|
$119
-
kW-mo/yr
|
- | - | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $347 | - |
$313
4,742
kWh
|
$34
-
kW-mo/yr
|
- | - | - | |
05 | 2.4321: Upgrade obsolete equipment | $411 | $2,300 |
$411
6,002
kWh
|
- | - | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,022 | $22,332 |
$6,386
96,434
kWh
|
$826
-
kW-mo/yr
|
- | $410 | $400 | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,098 | $23,216 |
$3,192
48,354
kWh
|
$352
-
kW-mo/yr
|
- | $209 | $345 | |
08 | 2.7134: Use photocell controls | $6,675 | $6,231 |
$6,517
98,748
kWh
|
$158
-
kW-mo/yr
|
- | - | - | |
09 | 2.7134: Use photocell controls | $539 | $199 |
$116
1,712
kWh
|
$9
-
kW-mo/yr
|
- | $109 | $305 | |
TOTAL RECOMMENDED | $24,781 | $55,037 |
$18,011
272,284
kWh
|
$1,498
-
kW-mo/yr
|
$3,494
-
MMBtu
|
$728 | $1,050 | ||
TOTAL IMPLEMENTED | $5,036 | $759 |
$1,389
21,034
kWh
|
$153
-
kW-mo/yr
|
$3,494
-
MMBtu
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs