Assessment Year | 2003 |
---|---|
Principal Product | Cold Rolled Steel Strips and Bars |
NAICS | 331221: Rolled Steel Shape Manufacturing |
SIC | 3316: Cold-Rolled Steel Sheet, Strip, and Bars |
Sales Range | $10 M to 50M |
# of Employees | 105 |
Plant Area |
143,283
ft2
|
Annual Production | 237,000,000
lb
|
Production Hrs. Annual | 6,140
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $392,579 | 6,413,365 |
kWh
|
$0.061 |
Electricity Demand | $66,085 | 17,429 |
kW-mo/yr
|
$3.79 |
Electricity Fees | $11,304 | - |
|
- |
Natural Gas | $9,599 | 1,504 |
MMBtu
|
$6.38 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $95,470 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $95,470 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,545 | $944 |
$2,147
39,645
kWh
|
$398
-
kW-mo/yr
|
- | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,854 | - |
$3,489
57,195
kWh
|
$365
-
kW-mo/yr
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $25,537 | $4,300 |
$23,131
379,181
kWh
|
$2,406
-
kW-mo/yr
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $46,841 | $42,958 |
$36,906
605,017
kWh
|
$4,482
-
kW-mo/yr
|
$1,193 | $4,260 | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,672 | $7,906 |
$1,169
19,131
kWh
|
$209
-
kW-mo/yr
|
$25 | $269 | |
06 | 2.7135: Install occupancy sensors | $1,725 | $4,016 |
$1,667
27,485
kWh
|
$58
-
kW-mo/yr
|
- | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $690 | $1,612 |
$329
5,396
kWh
|
$28
-
kW-mo/yr
|
$134 | $199 | |
08 | 2.6218: Turn off equipment when not in use | $12,606 | - |
$12,606
206,662
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $95,470 | $61,736 |
$81,444
1,339,712
kWh
|
$7,946
-
kW-mo/yr
|
$1,352 | $4,728 | ||
TOTAL IMPLEMENTED | $95,470 | $61,736 |
$81,444
1,339,712
kWh
|
$7,946
-
kW-mo/yr
|
$1,352 | $4,728 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs